You are here: CLASSE Wiki>CHESS Web>CHESS>OpsDocs>Reqform (20 Feb 2017, ljs30)Edit Attach
Tags

Weekly Tuesday Inspection Checklist-CHESS RUNNING

Operator on Shift:

qBEFORE Open Access begins, close all Secondary Gate Valves

qBEFORE Open Access ends, verify tunnel lights are off at C, D, F lines and G cave and all doors on Terranova racks in tunnel are closed

qDURING White Key Access, open all secondary gate valves

Signals for the past week: (complete during OWL shift)

qAll 7 Day Buttons

qNote Any Missing Signals

qPrint out plots of suspicious signals for distribution to the appropriate person

At Each Station and G-Cave:

qLook for badges, forms, parking permits, burn paper

qMove 2 “occupied” area badges from A1 user area to badge rack at Ops

qPrint out motor positions at each station, ops, and G-cave(prout we) & add printouts to binder in Ops

qCheck kapton window in A1, mylar window in F1 and replace if necessary

qCheck kapton window at I0 in F1 and replace if necessary

qCheck detector chiller fluid level in F2, and GE and Pilatus detectors if being used. Top off when necessary

In the Tunnel: (complete by 10am)

qVacuum/clean around ends of undulator magnets (4 spots)

qRecord D-line beamstop counter in vacuum labbook conference on webboard

qWater leaks

qIon pump controllers

qLoose wires

qOther obvious problems (look and listen)

qLook for missing bus/magnet covers, alert CESR operator and post webboard and ELOG notes.

qTurn off lights by C, D, and F lines and close all tunnel electronics racks as you go

At Operations

qOn EPICS Monitors:

qCheck for T.C. failures/overtemp

qCheck for ion pump trips

qCheck for disconnected signals/any other errors

qRemove group dosimeter log sheets weekly and individual dosimeter log sheets when they are full from binder, give to Dwight Widger

qEnsure broken equipment bench in ops is empty by either fixing equipment or giving to appropriate staff to fix

qVacuum computer fans & electronics

Misc. Stuff

qInventory Radiation Sources

qGlovebox: Check display screen for any alerts or alarms (box normally operates between 1-5mbar). Report anything suspicious (unlabeled vials, spilled materials, etc)

qCheck ice machine in cold room – break up/empty out large chunks as necessary

qCheck chem. rooms for obvious problems

qRun water through eye washes until it is clear.4 locations: G line chem room, main chem room, CHESS Ops, room off of F1

qCheck door intercoms (5th floor and loading dock)

qClear clutter from Ops/Prep area and experimental floor

F2 Cryo System

qCheck drip pans and buckets on East roof; empty as necessary

Post all of your findings to the Webboard

-- LeeShelp - 20 Feb 201
Topic revision: r1 - 20 Feb 2017, ljs30
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding CLASSE Wiki? Send feedback